Accessories
The AP310 has a set of custom-designed accessories to enhance performance.
The Ridley Universal Injector
The Ridley Universal Injector, designed exclusively for the AP310, features an ultra-wide range of operation from 0.1 Hz to above 30 MHz. It can provide a full 1 V rms output signal from 0.5 Hz to 30 MHz, and still has plenty of signal output available at its lowest range of 0.1 Hz. When used as a current injector, the low impedance of the isolator makes it capable of providing a minimum of 200 mA rms output from 1 Hz to above 30 MHz.
Output Impedance Injector
The Output Impedance Injector, designed to work with the Ridley Universal Injector, provides a convenient interface direct to the output of the power supply. It provides dc-blocking, and a current measurement port for direct connection to the AP310
Impedance Test Kit
The Ridley Impedance Test Kit is designed to measure power converter components, including capacitors of all types, inductors, and transformers. When used with the AP310, it can provide measurements of winding capacitance as low as 1 pF, and inductances as low as 3 nH. It can also provide sophisticated information such as the frequency dependence of transformer leakage inductance, and proximity loss values of winding resistances.
AP Interface
RidleyWorks® with AP Interface works intuitively with the AP310 Frequency Response Analyzer. This powerful tool will allow you to predict power supply transfer functions, and overlay measurements from the analyzer to ensure that the converter is working properly. RidleyWorks® is used by thousands of engineers worldwide to design production power supplies.